Installation, Administration and Maintenance
3.2 Static local configuration of a RFP
As an alternative to DHCP configuration, the RFPs/OMM may be individually
statically configured using the OM Configurator tool.
For a static local configuration you must use the java configuration tool
OpenMobility Configurator which requires Java Runtime Environment version
1.4 or higher.
The settings, which are configured on the RFP with the tool OM Configurator,
will be saved permanently in the internal flash memory of an RFP.
The parameters configurable via the OM Configurator comply with the DHCP
option, please see section 3.1 for details.
If a local static configuration has been done, DHCP is not used anymore.
The following figure shows the OM Configurator. Note, version number will
change with each OMM release.
To configure an RFP, at least the MAC address and all mandatory options
(see table below) have to be set. The MAC address must be entered in a
format such as xx-xx-xx-xx-xx-xx.
If the RFP has an IP address enter this address in the IP address field. In this
case you can reach the RFP from outside the local LAN segment. Optional.
To set additional parameters, press the “Add parameter” button and choose
the desired parameter.
IMPORTANT: Select the “yes” checkbox for the RFP to “Use local
configuration” otherwise DHCP will be used.
Aastra Telecom Page: 24 (47)