Operation Manual / TPL69-A10 / -A30 ... TPL77-A10 / -A30
9 Taking out of operation at short notice / 9.4 Blocking the inlets and
outlets
© Copyright 2018 . All rights reserved. HZTL2481_EN Revision C May 2018
9.4 Blocking the inlets and outlets
CAUTION
Shut off the lubricating oil supply to the turbocharger.
u Shut off compressor casing outlet, gas inlet and gas outlet by fitting
cover plates.
NOTICE
In this respect, refer to the engine manufacturer's instructions.
9.5 Bypass the turbocharger
CAUTION
Shut off the lubricating oil supply to the turbocharger.
w This applies to engines with one turbocharger only:
w The connections are ready and pipes for the bypass are available.
u Fit bypass around turbocharger.
NOTICE
In this respect, refer to the engine manufacturer's instructions.