2.Inverter-side connecter : SM02B-BHSS-1-TB(JST)
/ SM02(8.0)B-BHS-1(JST) or equivalent.
PIN NO. Function Comment
1 Cth VBLH(High voltage)
2 Ctl VBLL(Low voltage)
Electrical Specification:
AC-DC Electrical specification
3.4.1.1 Input Specification
No Item Condition Min. Typ. Max. Unit
1 Input Voltage ----- 100 --- 240 Vac
2 Input requency ----- 47 --- 63 Hz
3 Input Current ----- --- --- 1.0 Arms
Cold Start @Vin=100Vrms --- 30 A0-P
4 Inrush Current
Cold Start @Vin=240Vrms
---
--- 50 A0-P
5 Hold Up Time @full load & 100Vac input 10 --- --- ms
6 Turn on time Vin =110Vac --- 1.0 --- S
7 Efficiency Full load --- 70 --- %
8 Consumption Vin=240Vac,@ no load --- --- 1 W