TROUBLESHOOTING:
CAUSE SOLUTIONPROBLEM
1. SET POINT DIFFICULT TO SET OR
CANNOT BE REACHED
SUPPLY TEMPS NOT WITHIN
SPECIFIED LIMITS
HOT AND COLD SUPPLIES ARE
REVERSED
CHECK DIFFERENTIAL TEMPERATURE
BETWEEN SUPPLIES AND OUTLET
REINSTALL VALVE WITH SUPPLIES
CONNECTED TO MARKED INLETS
2. DOES NOT MAINTAIN OUTLET
TEMPERATURE OR CHANGES
FLUCTUATION IN SUPPLY
PRESSURES
FILTERS BLOCKED WITH DEBRIS
CHECK DIFFERENTIAL TEMPERATURE
BETWEEN SUPPLIES AND OUTLET
CLEAN FILTERS
OVER TIME
3. DISCHARGE TEMPERATURE TOO
HOT OR TOO COLD
VALVE NOT ADJUSTED PROPERLY READJUST VALVE TEMPERATURE PER
INSTALLATION INSTRUCTIONS
4. NO FLOW FROM VALVE HOT OR COLD SUPPLY FAILURE
OR SHUTOFFS CLOSED
OPEN SHUTOFFS OR RESTORE HOT
AND COLD SUPPLIES
CHECK FILTERS BLOCKED WITH
DEBRIS
CLEAN FILTERS
HOT
WATER
SUPPLY
COLD
WATER
SUPPLY
HOT
WATER
SUPPLY
COLD
WATER
SUPPLY
SV16 SHOWER
VALVE
SHOWERHEAD
TUB SPOUT
SV16 SHOWER
VALVE
DIVERTER
VALVE
SHOWERHEAD
HANDHELD SUPPLY
CONNECTION
HANDHELD
SHOWER
TYPICAL PIPING w/ TUB SPOUT
TYPICAL PIPING w/ HANDHELD SHOWER
SV16 Installation & Operation Manual
Date: 09/01/16

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Acorn SV16 and is the answer not in the manual?

Acorn SV16 Specifications

General IconGeneral
BrandAcorn
ModelSV16
CategoryControl Unit
LanguageEnglish