6
Invisible Operation
The unit is installed concealed above the ceiling. ACC-D is designed to intelligently create a comfortable and
healthy indoor air climate, while remaining invisible. This allows user to enjoy conditioned air without sacricing
room space or interior design creativity.
Flexibility In System Design
The unit offers fan motor that can operate up to 4 speeds, thus provide choices of external static pressure for
designing ducting system.
Easy Serviceability
With the concept of easy serviceability in mind, ACC-D series is designed for easy access to internal components.
The internal components, such as fan motor or blower, can be easily accessed for servicing through both sides
or bottom of the unit.
High Level Of Protection
The unit is incorporated with a unique safety feature, i.e. a oat switch, to provide an additional protection from
possible problems of condensate water over ow inside the unit. Once the condensate water reaches critical level,
the level switch will be activated and signal will be sent to the microprocessor controller to stop the compressor
as well as sending an error message to the wired controller, alerting the user, for further action.
Wired Remote Controller
The standard unit comes with the Netware III controller, which offers wide range of control features that, includes
7 days and 24 hours timer setting and more. The ACC-D series is able to communicate with the versatile NIM
network control module and offers the opportunity of one centralized control for a system of multiple indoor
units in a building.
Auto Random Restart
Auto random restart function allows the unit to automatic restart as the last setting condition when the power
supply is resumed after power failure. However, the compressor will restart randomly if more than one unit is
installed and sharing the same phase of power.
Self Diagnosis
The microprocessor provides the possibility to detect and diagnose any fault or malfunction that occurs in the
system. The error will be reected by the wired remote controller with a series of error code.