OPERATING INSTRUCTIONS (cont’d)
10
OPERATING INSTRUCTIONS (cont’d)
11
START OPERATION
3ODFHWKHSURGXFWLQDQXSULJKWSRVLWLRQRQDÀDWVWDEOHDQGKHDW
resistant surface. Make sure there is nothing flammable or heat
sensitive within 100cm (39 inches). Operating the product in any
other position could cause a hazard.
2. Insert the plug into a suitable wall socket. The dehumidifier is
suitable for operating on an electricity supply having the same
voltage as that shown on its rating label.
3. Make sure the water tank is correctly located. After switching on
the machine for the frst time, if the “Bucket Full” light illuminates,
pull out the water tank and check tha the “float lever is able to
move freely, then return the water tank to the correct position (Fig. 1).
DEFROST
When the machine is operated at low temperatures (less than 18°C) (64.4°F), the surface of the
evaporator may accumulate a layer of frost which would reduce the effciency of the machine.
When this happens the machine will go into periodic defrost mode. The machine will operate in
temperatures down to 5°C(41°F).The time taken to defrost may vary. If the machine freezes up, it
should be turned off at the power supply and re-started. If the room temperature remains below 5°C
(41°F) the machine should be switched off.
DEHUMIDIFYING
DEHUMIDIFYING MODE SELECTION:
7RWXUQWKHXQLWRQSUHVVWKH212))EXWWRQ
3UHVVWKHKXPLGLW\EXWWRQVWRVHOHFWDGHVLUHG5+RSHUDWLQJYDOXH
FAN SPEED SELECTION: Select a fan speed on the keypad. The speed you select is identifed by
the (illuminated) indicator light located directly above the selection mode.
'HKXPLGLI\LQJLVDPHDQVRIUHPRYLQJPRLVWXUHIURPWKHDLU$GHKXPLGL¿HUZLOOKHOSWRSURWHFW\RXU
home and valued possessions from damage (swelling) caused by moisture in the air. Essentially a
GHKXPLGL¿HUUHPRYHVPRLVWXUHIURPWKHDLUDVWKHPRLVWDLUSDVVHVRYHUDGHKXPLGLI\LQJHYDSRUDWRU
coil. Moisture is condensed on the evaporator coil, drained, and collected inside an internal
(removable) water tank located at the front of the unit. The exhausted air being returned into the
room environment is elevated several degrees, causing the surrounding air temperature to increase
(slightly). This process also contributes to lowering the relative humidity of the surrounding air.
BUCKET FULL LIGHT
• When the water tank is full the machine will stop and the“ Bucket
Full” light will illuminate.
• The water tank should be carefully removed from the machine by
sliding it outward from the front of the unit, and it should be emptied.
When the empty tank is replaced properly in the machine, the unit
will start up and run normally (Fig. 2).
NOTE: Please use both hands to carefully empty the water tank.
WATER FULL INDICATOR LIGHT (RED)
:KHQWKHZDWHUWDQNLVIXOODQGRULQFRUUHFWO\SRVLWLRQHGLQVLGHWKHFDELQHWWKHZDWHUIXOOUHGOLJKW
WXUQVRQDQGUHPDLQVRQXQWLOVXFKWLPHWKDWWKHWDQNLVHPSWLHGDQGRUFRUUHFWO\UHSRVLWLRQHG
This condition will result in the immediate shut down of the dehumidifying system (both compressor
and fan motor operations are terminated). This is a safety feature. When the water tank is emptied
DQGRUFRUUHFWO\UHSRVLWLRQHGWKHGHKXPLGL¿HUZLOOUHVXPHRSHUDWLRQDXWRPDWLFDOO\
NOTE: It may take several minutes before operating conditions resume.
FACTORY DEFAULT SETTING
+XPLGLW\6HWWLQJ)DQ6SHHG/RZ
NOTE: In the event of a power failure, the unit will default to the last program setting that was used
when power is restored
WATER TANK OPERATION
3URSHULQVWDOODWLRQRIWKHZDWHUWDQNLVFUXFLDOLQPDLQWDLQLQJUHOLDEOHGHKXPLGL¿HURSHUDWLRQ7KH
water tank holds accumulated condensed water and, by means of a safety switch, controls both
WKHZDWHUOHYHODQGRSHUDWLRQRIWKHGHKXPLGL¿FDWLRQSURFHVV:KHQWKHZDWHUWDQNLVIXOODQGRU
DFFLGHQWDOO\GLVSODFHGLQVLGHWKHFDELQHWWKHÀRDWVZLWFKDFWXDWRULQVLGHWKHWDQNEUHDNVFRQWDFW
with the safety switch. This condition results in the immediate shut down of the compressor and fan
motor system, preventing moisture from being condensed.
NOTE:1HYHUWDPSHUZLWKRUDWWHPSWWRGHIHDWWKHZDWHUOHYHOVDIHW\ÀRDWVZLWFKV\VWHP
Fig. 1
Fig. 2
Fig. 2
Fig. 3
AIR FILTER
<RXUGHKXPLGL¿HUIHDWXUHVDUHPRYDEOH$LU)LOWHU7KLV¿OWHULVORFDWHG
at the front of the unit (behind the air intake grill) directly above the
water tank compartment. The air filter plays an important role in
KHOSLQJWRUHGXFHPLQLPL]HGXVWGLUWSDUWLFOHVIURPWKHVXUURXQGLQJ
HQYLURQPHQW$EORFNHG FORJJHG DLU IOWHU UHGXFHVDLULQWDNH
impacting negatively on operating effciency. To maintain maximum
RSHUDWLQJHI¿FLHQF\WKH¿OWHUPXVWEHFKHFNHGDQGFOHDQHGUHJXODUO\
(every 2 weeks). More frequent cleaning may be required
depending upon indoor air quality.
IMPORTANT:1HYHURSHUDWHWKHXQLWZLWKRXWWKHDLU¿OWHULQSODFH
AIR FILTER CLEANING STEPS:
3XOOWKHDLU¿OWHURXWJHQWO\)LJ
&OHDQWKH¿OWHUZLWKDYDFXXPFOHDQHURUZDVKLWZLWKFOHDQZDWHU
and dry with a dry cloth
3XWWKHFOHDQDLU¿OWHUEDFNLQSODFHDQGFRQWLQXHWRRSHUDWHWKH
GHKXPLGL¿HU
AeonAir.com
TM
AeonAir.com
TM
Float lever
(does not include TIMER setting).