Introduction
Chapter 112
* These uncertainties only apply to Option 033
Table 1-4 Typical measurement uncertainties of Calibration Factor (CF) data printed on
the power sensor
Frequency 25°C ± 3°C
8487A 8481B 8482B 8481H 8482H 8487D 8485D 8481D
100 kHz to 10 MHz - - 1.50 - 0.91 - - -
10 MHz to 30 MHz - 1.48 1.44 0.86 0.81 - - 0.77
30 MHz to 500 MHz 1.38 1.48 1.51 0.88 0.92 1.33 1.24 0.81
500 MHz to 1.2 GHz 1.34 1.48 1.48 0.87 0.88 1.35 1.26 0.81
1.2 GHz to 6 GHz 1.41 1.54 1.53 0.98 0.95 1.41 1.35 0.97
6 GHz to 14 GHz 1.59 1.71 - 1.36 - 1.62 1.63 1.20
14 GHz to 18 GHz 1.69 1.99 - 1.71 - 1.73 1.83 1.72
18 GHz to 26.5 GHz2.23----2.252.45-
26.5 GHz to 33 GHz2.58----2.552.94*-
33 GHz to 34 GHz2.73----3.08--
34 GHz to 35 GHz2.73----3.08--
35 GHz to 40 GHz2.73----3.08--
40 GHz to 45 GHz3.67----4.28--
45 GHz to 50 GHz4.33----4.72--