Functional control panel
The heating system is fitted with modern electronics that allow
you to control everything yourself or let the auto functions to
do nearly everything. For example, Compact 3010 knows
whether you are connected to the 230 volt supply, and then
prioritises that as the energy source.
The control panel is divided into three menu categories:
Information menu. This shows time, temperature and what is
connected to the Compact 3010.
Settings menu. This is where you set the basic settings for
heating, such as desired temperature, extra hot water and
energy selection.
Tools menu. This is where you can adjust and connect extra
functions to the Compact 3010.
Control the heating yourself.
Or let the auto functions do the job for you
Information menu
Circulation pump
Shows when the circulation pump is
operating.
Interior temperature
Shows interior temperature
Outside temperature
Shows outdoor temperature (if sensor is
fitted)
Clock
Shows date and time
On/Off button
Main switch for the boiler.
230 volt
Shows when 230 V is connected to the
boiler.
Bottle switch
Shows when the automatic switch
for the LPG bottles is connected and
activated.
MENU button
Settings menu button.
Settings menu.
Setting desired interior temperature
The temperature can be set from +5 °C to
+30 °C in 0.5 °C intervals.
Heating with the 230 V element.
Three power levels 1, 2 or 3 kW. The
higher the power level you use, the quicker
the heating.
LPG heating
The boiler is heated by the LPG burner. The
power is automatically controlled by the
heating requirement.
Extra hot water
If you need more hot water the boiler
can temporarily raise the hot water
temperature from 50 °C to 65 °C. After
30 minutes, the boiler returns to normal
operation. The circulation pump does
not run at this time.
Tools menu
From the settings menu you can con-
tinue to the tools menu with the other
control panel functions seen below.
Button sounds
Tools / Key
Light strength
Service functions
Panel reset
Tools menus
Clock
Automatic temperature change
(night-time mode)
Automatic start
Load sensor
Constant pump operation
Pump auto / 12 V
Pump speed
Bottle switch
Offset (temperature adjustment)
Automatic temperature boost
(legionella)
Languages
External start (GSM)

Other manuals for Alde Compact 3010