ALLEN&HEATH XB-14 service manual AP7566 Page - 5 - of 13
Servicing Precautions – General Notes
Service personnel:
Service work should be carried out by technically qualified service personnel only.
Mains power is dangerous and can kill. Do not attempt to work on a linear or switched
mode power supply if you are not suitably qualified to do so. Do not attempt to repair
surface mount circuit assemblies unless you are suitably qualified and have the
necessary facilities to do so. Replacement circuit assemblies can be ordered.
Service facilities:
Ensure a suitably sized work surface is available. Ensure this is clear of dirt, debris and
obstructions which may damage the equipment surfaces. Ensure adequate lighting.
Use the correct tools for the job and ensure they are in good working order. Ensure all
workshop safety requirements are adhered to.
Service information:
Check that you have all the information you need before starting the service job. Refer
to the Allen & Heath web site or contact Allen & Heath technical support for details on
the latest information. Full technical information can be downloaded from the web site
Distributor Zone (password required).
Mains power:
Connect the equipment to mains power only of the type described in the user guide and
marked on the rear panel. The power source must provide a good ground connection.
Ensure you always use an isolation transformer when working on any mains power
supply unit.
Mains cord and fuse:
Use the correct power cord as supplied with the equipment. Do not remove or tamper
with the ground connection in the power cord. Heed the Important Mains Plug Wiring
Instructions printed in the user guide if it is necessary to rewire the mains cord. Always
replace the equipment mains fuse with the correct type and rating as described in the
user guide and marked on the equipment panel.
Opening the unit:
Switch off and remove the mains power cord before opening the equipment. Ensure all
power supply covers and safety shields are in place before applying power with the unit
open for diagnostic fault finding.
Closing the unit:
Before finishing, check the quality and accuracy of the service work carried out.
Remove any dirt or debris as this may cause equipment failure in the future. Ensure all
assemblies, harnesses and connectors are correctly aligned and plugged in. Ensure
that jumper settings and control configurations are correctly set according to the
requirements of the customer.
Continued -

Other manuals for ALLEN & HEATH XB-14

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ALLEN & HEATH XB-14 and is the answer not in the manual?

ALLEN & HEATH XB-14 Specifications

Operating Levels IconOperating Levels
Mono channel Mic input range+6 to –63dBu
Mono channel Line input range+10 to –26dBu
Insert point nominal level0dBu
Stereo input nominal level0dBu
Telco channel input range+10 to –26dBu
External monitor inputs nominal level0dBu
Output Levels IconOutput Levels
PGM L & R outputs nominal level+4dBu
PGM Mono output nominal level0dBu
PGM L & R inserts nominal level-2dBu
Aux output nominal level0dBu
Mix B outputs nominal level0dBu
Rec outputs nominal level0dBu
Audio Performance IconAudio Performance
THD+n Mic in to PGM L/R Out0.003%
THD+n Mic in to PGM Out0.007%
THD+n Line in to PGM L/R out0.004%
THD+n Stereo in to PGM out0.003%
Noise Mic Pre EIN-127dBu
Noise PGM out-92dBu
Frequency Response IconFrequency Response
Mic in to PGM L/R Out20Hz to 20kHz
Line in to PGM L/R out10Hz to 30kHz
Stereo in to PGM L/R out10Hz to 30kHz
Headroom IconHeadroom
Analogue Headroom Outputs21dB
USB in & out headroom14dB
Analogue Headroom Mix point24dB
Crosstalk & Attenuation IconCrosstalk & Attenuation
Mono fader attenuation 1kHz/10kHz-99/-90
Mono ON switch attenuation 1kHz/10kHz-96/-80
TELCO fader attenuation 1kHz/10kHz-99/-92
TELCO ON switch attenuation 1kHz/10kHz-102/-100
Stereo fader attenuation 1kHz/10kHz-100/-91
Stereo ON switch attenuation 1kHz/10kHz-102/-102