Rockwell Automation Publication PFLEX-AP005B-EN-P - May 2019 53
Drive Selection Considerations Chapter 1
Table 34 - PowerFlex 700 Drive Catalog Number Explanation (continued)
20B D 2P1 A 3 A Y N A E C 0 NN AD
a b c1…c5 d e f g h i j k l m n
c5
ND Rating
690V, 50 Hz Input
Code Amps kW Frame
052 52 45 5
060 60 55 5
082 82 75 5
098 98 90 6
119 119 110 6
142 142 132 6
e
HIM
Code Operator Interface
0 Blank Cover
3 LCD Display, Full Numeric Keypad
J
Remote (Panel Mount), IP66, NEMA/UL Type 12 Full
Numeric LCD HIM
K
Remote (Panel Mount), IP66, NEMA/UL Type 12 Prog. Only
LCD HIM
Available with Frames 5…6 Stand-Alone IP54 drives (Enclosure Code
"G").
f
Documentation
Code Type
A Manual
N No Manual
Q
No Shipping Package (Internal Use
Only)
g
Brake
Code w/Brake IGBT
Y Yes
N No
Brake IGBT is standard on Frames 0-3, optional on Frames 4-6.
h
Internal Braking Resistor
Code w/Resistor
Y
Yes
N No
Not available for Frame 3 drives or larger.
j
Comm Slot
Code Network Type
C ControlNet (Coax)
D DeviceNet
E EtherNet/IP
N None
k
Control & I/O
Code Control I/O Volts
A Standard 24V DC/AC
B Standard 115V AC
C Vector Δ 24V DC
D Vector Δ 115V AC
N Standard None
Δ Vector Control Option utilizes DPI Only.
l
Feedback
Code Type
0 None
1 Encoder, 12V/5V
m
Future Use
n
Special Firmware (Frames 0…6 Only)
Code Type
AD 60 Hz Maximum
AE Cascading Fan/Pump Control
AX 82 Hz Maximum
BA Pump Off (for pump jack)
Must be used with Vector Control option C or D (Position k). Positions
m-n are only required when custom rmware is supplied.
d
Enclosure
Code Enclosure
A IP20, NEMA/UL Type 1
F
Open/Flange Mount
Front: IP00, NEMA/UL Type Open
Back/Heatsink: IP54, NEMA Type 12
G
Stand-Alone/Wall Mount
IP54, NEMA/UL Type 12
Only available for Frame 5 & Frame 6 drives, 400…690V.
i
Emission
Code CE Filter § CM Choke
A Yes Yes
B # Yes No
N No No
§ Note: 600V class drives below 77 Amps (Frames 0-4) are declared to
meet the Low Voltage Directive. It is the responsibility of the user to
determine compliance to the EMC directive.
# Only available for 208…240V Frame 0-3 drives.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley Rockwell Automation PowerFlex 700 Series and is the answer not in the manual?

Allen-Bradley Rockwell Automation PowerFlex 700 Series Specifications

General IconGeneral
BrandAllen-Bradley
ModelRockwell Automation PowerFlex 700 Series
CategoryDC Drives
LanguageEnglish

Related product manuals