Rockwell Automation Publication 1783-IN022A-EN-P - July 2023 6
Stratix 5200 Ethernet Managed Switches Installation Instructions
• Temperature surrounding the unit does not exceed 60 °C (140 °F).
• For 10/100 ports and 10/100/1000 ports, the cable length from a switch to an attached device cannot exceed 100 m (328 ft).
• Cabling is away from sources of electrical noise, such as radios, power lines, and fluorescent lighting fixtures.
• This device must be installed in the vertical position
Mount the Switch
The rear panel of the switch has a latch for installation on a DIN rail. The latch is spring-loaded to move down to position the switch over a DIN rail and return to the original position
to secure the switch to a DIN rail.
To mount the switch on a DIN rail, follow these steps.
1. Position the switch so that the lower edge and spring of the DIN clip, which is located within the bottom of the DIN rail bracket, engages with the bottom section of the DIN
rail.
2. Push up to compress the spring.
3. Rotate the switch so that the top hook of the DIN clip clamps to the top section of the DIN rail.
IMPORTANT When the switch is installed in an industrial enclosure, the temperature within the enclosure is greater than normal room temperature outside
the enclosure. The temperature inside the enclosure cannot exceed 60 °C (140 °F), the maximum ambient enclosure temperature of the switch.
IMPORTANT The switch must be mounted in an upright orientation, as shown in these instructions. Alternative mounting orientations are not supported.