maintenance guide
48
Tools
Time
15 min
1
Remove the silencer Isolate the gas supply. Remove the four
screws and disconnect the gas pipe from
the gas valve
Pull the assembly towards you
2
Note: Any work carried out on the
combustion assembly requires
a combustion analysis check on
completion of work
Remove the three screws to free the burner
door
Pull the burner toward you
11
33
22
1.Stainless Steel Burner
Power Length Venturi
24 KW 104.6 mm Ø 42 mm
30 KW 135.8 mm /
2. Ignition electrode
3.Detection electrode 38 KW 167 mm /
Burner