Page #14 background image
14
NON
volatile errors
(the appliance is
unable to work until
the error has been
solved and a manual
reset has been
done)
50 °C, 70 °C, 80 °C and
corresponding “WAVES”
icons switched on
HE2 functional relay stuck due to:
- faulty component if a short circuit occurs between
the HE2 power terminals on the PCB, replace the PCB.
40 °C and corresponding
“WAVES” icons
switched on
Internal fault
Replace the PCB.
Volatile errors
(the appliance is
able to work; if the
error disappears, the
appliance resumes
normal operation)
60 °C, 70 °C and
corresponding “WAVES”
icons switched on
Low heating rate concerning the outlet tank due to:
- incorrect appliance horizontal installation if the
water pipes are on the right, dismount the product
from the wall and make the proper installation;
- bad placed or damaged wiring if the red power
cable is disconnected/damaged, connect/replace it;
- faulty component if the ohmic resistance value
between the HE1 fastons is not in compliance with the
nominal value (R ~ 35 Ω), replace it.
50 °C, 60 °C, 70 °C and
corresponding “WAVES”
icons switched on
Low heating rate concerning the inlet tank due to:
- incorrect appliance horizontal installation if the
water pipes are on the right, dismount the product
from the wall and make the proper installation;
- bad placed or damaged wiring if the blue power
cable is disconnected/damaged, connect/replace it;
- faulty component if the ohmic resistance value
between the HE2 fastons is not in compliance with the
nominal value (R ~ 53 Ω), replace it.
60 °C and corresponding
“WAVES” icons
switched on
HE1 probe short/open circuit due to:
- bad placed or damaged wiring/faulty component if
the component is disconnected or faulty (sensor/s
values not in compliance with “Sensor Test Table”),
connect/replace it.
50 °C, 60 °C and
corresponding “WAVES”
icons switched on
HE2
probe short/open circuit due to:
- bad placed or damaged wiring/faulty component if
the component is disconnected or faulty (sensor/s
values not in compliance with “Sensor Test Table”),
connect/replace it.
60 °C, 80 °C and
corresponding “WAVES”
icons switched on
High difference of
temperature measured by higher and
lower sensors into the outlet tank due to:
- HE1 probe incorrect positioning if the component is
not entirely into the HE1 sheath, place it in the right
position;
- HE1 sensor/s out of tune if the component is faulty
(values not in compliance with “Sensor Test Table”),
replace it.
50 °C, 60 °C, 80 °C and
corresponding “WAVES”
icons switched on
High difference of temperature measured by higher and
lower sensors into the inlet tank due to:
- HE2 probe incorrect positioning if the component is
not entirely into the HE2 sheath, place it in the right
position;
- HE2 sensor/s out of tune if the component is faulty
(values not in compliance with “Sensor Test Table”),
replace it.