42 Issue 2008-11-13 1004935-US-1.0
16 Maintenance plan
Regular inspections shall be made according to national regulations by a trained and
qualified person. The number of service occasions shall be in accordance with
national requirements. This is especially important when the installation concerns a
fire-approved door or a door with an emergency opening function.
As with all other technical products, an automatic door needs maintenance and ser-
vice. It is essential to know the importance of maintenance to have a reliable and safe
product.
Service and adjustments will ensure a safe and proper operation of an automatic door
unit.
The table below shows the recommended interval, in months, when to replace parts
during preventive maintenance.
Part Part Number
Cycles/hour in operation
Abusive
Environment
<10 <100 >100
Low
Traffic
Medium
Traffic
High
Traffic
Vibration absorbers and oil plug 1003882 24 12 6 6
SAS-F Service Kit 1003888 24 12 6 6
PULL Service Kit 1003886 24 12 6 6
Limit Switch 655614 24 12 6 6
Capacitor 655599 60 60 60 60
CSDB-120 Control Unit 1004204 60 60 60 60
HAZARD WARNING!
Failure to observe this information may result in minor personal injury
or damage to equipment.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Assa Abloy Besam PowerSwing CSDB and is the answer not in the manual?

Assa Abloy Besam PowerSwing CSDB Specifications

General IconGeneral
BrandAssa Abloy
ModelBesam PowerSwing CSDB
CategoryGarage Door Opener
LanguageEnglish

Related product manuals