8 Technical data
8.1 Reference conditions and limitations
Reference conditions
Unit
Compressed air inlet pressure bar(e) 7
Compressed air inlet pressure psig 101.53
Compressed air inlet temperature ˚C 35
Compressed air inlet temperature °F 95
Ambient temperature °C 25
Ambient temperature °F 77
Dewpoint °C 3
Dewpoint °F 37.4
Limits
Unit
Maximum compressed air inlet pressure bar(e) 13
Maximum compressed air inlet pressure psig 188.5
Minimum ambient temperature °C 5
Minimum ambient temperature °F 41
Maximum ambient temperature °C 43
Maximum ambient temperature °F 110
Maximum compressed air inlet temperature °C 55
Maximum compressed air inlet temperature °F 122
8.2 Air dryer data
FX 1 up to FX 5 - 230 V 50 Hz
Air dryer type Unit FX 1 FX 2 FX 3 FX 4 FX 5
Nominal power W 130 164 190 266 284
Nominal power hp 0.17 0.22 0.25 0.36 0.38
Electric power input, compressor W 101 135 161 233 251
Electric power input, compressor hp 0.135 0.181 0.216 0.312 0.337
Electric power input, fan motor W 29 29 29 33 33
Electric power input, fan motor hp 0.039 0.039 0.039 0.044 0.044
Weight of the unit kg 19 19 20 25 27
Weight of the unit lb 41.9 41.9 44.1 55.1 59.5
Instruction book