2920 1461 03
21
User manual
4 Quick look at actual compressor
status
Procedure
1. Starting from the Main screen (see section 3.2), press the ¯
key: A screen similar to the one below appears:
Auto Operation
Local Control
Timer Active
Main Help Xtra ¯
F1 F2 F3
Fig. 4.1 Example of an actual compressor status display
Line 1 indicates the automatic or manual operation status of
the regulator:
Auto operation means that the regulator automatically
adapts the operation of the compressor, i.e. loading,
unloading, stopping and automatic restarting according to
the programmed parameters.
Man operation means that the automatic pressure control
function of the regulator is interrupted after pressing the
Unload key on the Main screen.
Line 2 indicates whether the regulator operates in local control
or remote control mode:
Local control means that the start/stop and load/unload
buttons on the keyboard are activated.
Remote control means that these functions are controlled
remotely. Consult Atlas Copco.
Line 3 indicates whether the timer which generates time-based
start and stop commands is activated or not. See section 13.
See section 2.3 for the functions of the keys Main, Help
and Xtra.
2. Press the ¯ key to get other data (actual compressor
conditions of the compressor) as shown in Figs. 3.1.
5 Status data menu
The status data submenu gives information regarding the status
of the compressor protection functions (shut-down, shut-down
warning, service warning and warning) and allows resetting of
a shut-down, motor overload and service condition.
Procedure
Starting from the Main screen (see section 3.2):
- Press the key Menu (F1), the option Status data will be
followed by a horizontal arrow
- Press the tabulator key (5)
5.1 No message exists
In this case, LED (7) is out and the message on the display
indicates that all conditions are normal (Fig. 5.1):
All conditions
are OK
Menu
F1 F2 F3
Fig. 5.1 Example of a status data screen
5.2 A shut-down message exists
In case the compressor is shut down, LED (7) will blink.
In case of a shut-down due to too high a temperature at the
compressor element outlet, a screen similar to the one below
will appear:
Element outlet
C 122
Shd Max 120
Menu ** ** Rset
F1 F2 F3
Fig. 5.2 Example of a status data screen
1. The indicators (**) are blinking. The screen shows the
sensor (compressor element outlet), the actual reading (122
degrees Celsius), that the compressor is shut down (Shd),
and the shut-down setting (120 degrees Celsius).
2. It remains possible to scroll through other menus, e.g. to
check the values of other parameters.
When returning to the Status data menu, the option
Shutdowns will blink. This option can be selected by
pressing the tabulator key (5) to return to the shut-down
screen (Fig. 5.2).
52237F
8
11
710
612
3
2
1
9
4
5
4
9
S3
9

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco GA5 and is the answer not in the manual?

Atlas Copco GA5 Specifications

General IconGeneral
BrandAtlas Copco
ModelGA5
CategoryAir Compressor
LanguageEnglish

Related product manuals