6 Adjustments and servicing procedures
6.1 Pressure switch
Pressure switch
General
The adjustment of the maximum or stopping pressure of the compressor is effected by means of the air pressure
switch. The switch also controls the pressure difference between the maximum pressure (stopping pressure)
and the pressure at which compression is resumed (starting pressure).
Caution
Adjust the air pressure switch while the switch is pressurized.
Switch off the voltage before removing the cover of the switch; reinstall it after an adjustment
has been made and before the voltage is switched on again.
Instruction book
2920 7002 03 35