EasyManuals Logo
Home>Atlas Copco>Air Compressor>ZT Series

Atlas Copco ZT Series User Manual

Atlas Copco ZT Series
66 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #20 background imageLoading...
Page #20 background image
Instruction book
2920 1472 03 20
Warning
If activated and provided the module was in the automatic operation mode, the compressor will
automatically restart if the supply voltage to the module is restored within a programmed time period.
The power recovery time (the period within which the voltage must be restored to have an automatic
restart) can be set between 1 and 255 seconds or to Infinite. If the power recovery time is set to
Infinite, the compressor will always restart after a voltage failure, no matter how long it takes to restore
the voltage. A restart delay can also be programmed, allowing e.g. two compressors to be restarted
one after the other.
1.9 Control panel
Fig. 1.10 Control panel
1.9.1 LEDs/buttons/keys
Ref. Designation Function
1 Start button Push button to start the compressor. LED (8) lights up,
indicating that the Elektronikon regulator is operative.
2 Display Indicates messages concerning the compressor operating
condition, a service need or a fault.
3 Scroll keys Keys to scroll upwards or downwards through the display.
4 Tabulator key Key to select the parameter indicated by a horizontal arrow.
Only the parameters followed by an arrow pointing to the right
are accessible for modifying.
5 Function keys Keys to control and program the compressor. See section 1.9.3.
6 Voltage on LED Indicates that the voltage is switched on.
7 General alarm LED Is alight if a shut-down warning condition exists. See section
1.8.2.
7 General alarm LED Blinks if a shut-down condition exists, if an important sensor is
out of order or after an emergency stop. See section 1.8.2.
8 Automatic operation LED Indicates that the regulator is automatically controlling the
compressor.
9 Stop button Push button to stop the compressor. LED (8) goes out.
S3 Emergency stop button Push button to stop the compressor immediately in case of
emergency. After remedying the trouble, unlock the button by
pulling it out.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco ZT Series and is the answer not in the manual?

Atlas Copco ZT Series Specifications

General IconGeneral
BrandAtlas Copco
ModelZT Series
CategoryAir Compressor
LanguageEnglish

Related product manuals