4 Product description BECKHOFF Drive Technology
18 Version 6.2 AX5000
4.4 Technical data
It is essential to observe chapter 3.3 if you wish to operate an AX5000 in
4.4.1 Permissible ambient and operating conditions
Ambient / operating conditions
Ambient temperature during operation
Ambient temp. during transport/storage
5 % to 95 %, non-condensing
2 according to EN 60204/EN 50178
Under extreme operating conditions separate
measures must be agreed with the manufacturer.
up to 1000 m above sea level without reduced power
Between 1000 m and max. 3000 m with reduced
Total device current ≤ 3 A: free convection
Total device current > 3 A: built-in temperature-
Vibration test (EN 60068-2-6)
Frequency range: 10-500 Hz
Amplitude: 10-58 Hz = 0,075 mm pk-pk
Shock test (EN 60068-2-27)
Half sine wave amplitude: 5 g
Duration: 30 ms
Number of shocks: 3 per axis and direction
Repetitive shock test (EN 60068-2-27)
Half sine wave amplitude: 5 g
Duration: 30 ms
Number of shocks: 1000 per axis and direction