BECKHOFF Drive Technology 4 Product description
AX5000 Version 6.2 25
4.7 Overview of connectors/terminal points
4.7.1 X01 - wide voltage input
Terminal point
0,5 -0,6 Nm
4.7.2 X02 - DC link (AX5101 - AX5125 und AX520x)
external brake resistor
and drive system
0,5 -0,6 Nm
4.7.3 X02 - DC link (Only AX5140)
only for drive system 1,2 -1,5 Nm
WARNING
Serious risk of injury through high electrical voltage!
875 V DC voltage at the DC link terminals. Dangerous voltage may be
present for 5 minutes after the device is switched off. Measure the voltage
at the DC link contacts DC+ and DC-. The device is safe once the voltage
has fallen below 50 V.
Remove the connector only if you want to build a drive system with a AX-
Bridge. Remove the white hexagon plugs only if you wire the terminal
4.7.4 X03 - 24 V
DC
supply
p
24 V
DC ±10 (depending on the
connected consumers
0,5 – 0,6 Nm
s
24 V
DC ±25%
18 A – 25 A = 1,1 A