System overview
RC66 | 08-2021
10
Blum-Novotest GmbH
3.4 Technical data
3.4.1 Dimensions
Fig. 3-3 Dimensions [mm] RC66.
Protection class IP68
Operating voltage U
B
(stabilised DC voltage) 1213V / 100mA via interface
Signal transmission Radio
Frequency band 2.42.5GHz
Max. transmission power 0dBm
Transmission range 15m – see 3.5 Area of work
Min. bending radius cable 60mm (application: flexible)
Max. cable length 50m
Storage temperature -20 ... +70 °C
Operating temperature +5 ... +50 °C
Ø 44
9,5
55
Ø 20…38
3,2 Ø 6
Ø 3,3 (M4)
45
37
Ø 6,3
Ø 40
1 2
3
4 5
(1) Machine wall opening
(2) O-ring 40× 2(NBR 70)
(3) 4× holding screws M3×10 (ISO 4726)
(4) 4× holding screws M4×10 (ISO 4726)