EasyManuals Logo
Home>BLUM>Servo Drives>SERVO-DRIVE

BLUM SERVO-DRIVE Instruction Leaflet

BLUM SERVO-DRIVE
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #28 background imageLoading...
Page #28 background image
28
Technical data
The appliances must only be used in dry, closed rooms. All SERVO-DRIVE appliances are of protec-
tion class III and must only be supplied with safety extra-low voltage (SELV). They are only to be used
with the transformers provided by Blum.
Input voltage: ..........................................................................100–240 V a.c. ±10% / 5060 Hz ±10%
Input current: ................................................................................................................................. 0.6 A
Output power: ............................................................................................................................ 24.0 W
Output voltage: ..................................................................................................................... 24.0 V d.c.
Output current: .............................................................................................................................. 1.0 A
Ambient temperature: ...................................................... 0 to +4C / 5 to 80% r.H. non condensing
Protection category: ....................................................................................................................... IP40
Average active efficiency: .............................................................................................................. 86.8%
Efficiency at low load (10%): .........................................................................................................84.0%
No-load power consumption: .................................................................................................... <0.08 W
Maximum altitude: ............................................................2000 m (at an ambient temperature of 25°C)
24-Watt Blum transformer Z10NE030
12-Watt Blum transformer Z10NA300
Input voltage: ..........................................................................100–240 V a.c. ±10% / 5060 Hz ±10%
Input current: ................................................................................................................................. 0.3 A
Output power: ............................................................................................................................ 12.0 W
Output voltage: ..................................................................................................................... 24.0 V d.c.
Output current: .............................................................................................................................. 0.5 A
Ambient temperature: ...................................................... 0 to +4C / 5 to 80% r.H. non condensing
Protection category: ....................................................................................................................... IP44
Average active efficiency: .............................................................................................................. 83.3%
Efficiency at low load (10%): .........................................................................................................78.0%
No-load power consumption: .................................................................................................... <0.08 W
Maximum altitude: ............................................................2000 m (at an ambient temperature of 25°C)

Other manuals for BLUM SERVO-DRIVE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BLUM SERVO-DRIVE and is the answer not in the manual?

BLUM SERVO-DRIVE Specifications

General IconGeneral
BrandBLUM
ModelSERVO-DRIVE
CategoryServo Drives
LanguageEnglish

Related product manuals