Mounting and commissioning
26 by Blum-Novotest 2012
MODE SET
Transmission
mode
Normal
standard adjustment
Robust
ambient conditions with
radio interferences
high chip pollution
Fast
fast measuring speeds
interference-free ambient
conditions
Switch-on
time
Fast
fast switch-on time
setting decreases battery
life
Normal
normal switch-on time
standard setting
Slow
low switch-on time
setting increases battery life
not suitable for switch
on/off impulse controlled
Probe type
Standard
ready for activation
1)
setting decreases battery
life
EcoMode
ready for activation
2)
setting increases battery life
TWIN A
setting for double spindle
machines:
set first probe to TWIN A
set second probe to TWIN B
TWIN B
Automatic display of the basic adjustments
Standby
BU
RD
OG
GN
GN
RD
GN
BU
OG
BU
RD
GN