EasyManuals Logo
Home>Bosch>Heat Pump>200 R

Bosch 200 R User Manual

Bosch 200 R
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #32 background imageLoading...
Page #32 background image
Installation information for cylinder without solar coil
200-300 R/C, 200-300 R, 360 C – 6 720 801 192 (2017/07)
32
Fig. 69 Ceiling connection dimensions 200
Fig. 70 Ceiling connection dimensions 300
Filling the water heater
Anode
For extra safety there is an electronic sacrificial anode installed in the
water heater (model R). The task of the anode is to protect against
corrosion to give the water heater a longer service-life. In cases where
there are thought to be high amounts of chlorides in the water (>10 mg/
litre), inspect the anode every 1-2 years. The anode (aluminium) which
is on the top of the water heater has an original diameter of 20 mm. If it
has been affected, e.g. its diameter has been reduced to 5-8 mm or is 10
cm long, it should be replaced and re-inspected after 2-3 years.
Pressurise the water heater (outer-shell first).
Shut off the main cold water supply.
Open the venting cock.
Unscrew the anode at the top of the water heater, check and replace
if necessary.
In confined spaces (low ceiling heights) a chain anode is available as an
alternative. Order anodes from your local installer specifying the tank
model.
Technical data
WARNING: The water heater can crack if filling is
performed in the wrong order.
Fill and pressurise the water heater before filling the
heating system.
Do not forget to vent after filling the outer shell and
commissioning the system.
6720646738-07.1I
396
100
100
45˚
198
= =
6720646738-08.1I
471
100
100
238,5
45˚
36˚
= =
Model Unit 200 R 300 R 200 C 300 C
Volume of hot water litres 185 286 185 286
Outer shell volume litres 105 176 105 176
Hot/cold connection Cu 22 28 22 28
Outer shell
connection
inches G25
Submerged tube
sensor
mm 9,5
Immersion heater
connection
inches -2-2
Working pressure
radiator
bar 32,532,5
Working pressure
hot water
bar 10
Aluminium anode Yes Yes --
Dimensions
(WxDxH)
mm 600x600
x1520
695x695
x1700
600x600
x1520
695x695
x1700
Weight kg 97 136 108 151
Table 2 Technical data