9.2 Outdoor Unit - BMS500-AAM027-1CSXRC,
BMS500-AAM018-1CSXHC, BMS500-AAM027-1CSXHC
9.2.1 Removing the panel plate
1. Stop operation of the system and turn “OFF” the power at the disconnect.
2. Remove the big handle (4 screws).
Figure 110
Screws of
big handle
3. Remove the top cover (4 screws).
Figure 111
Screws of top cover
4. Remove the right side panel (1 screw).
Figure 112
Screw
5. Remove the front panel (8 screws).
Figure 113
Screws of front panel

Table of Contents

Other manuals for Bosch Climate 5000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Climate 5000 Series and is the answer not in the manual?

Bosch Climate 5000 Series Specifications

General IconGeneral
SEER RatingUp to 22
HSPF RatingUp to 10
Wi-Fi ConnectivityYes
Cooling Capacity9000 - 24000 BTU/h
Energy Efficiency Class (Cooling)A+++
Energy Efficiency Class (Heating)A+++
Sound Power Level (Indoor Unit)19 - 45 dB
Sound Power Level (Outdoor Unit)Varies by model, typically 50-60 dB(A)
FeaturesSleep mode, Timer, Self-Cleaning Function
Energy Efficiency Ratio (EER)Varies by model
Coefficient of Performance (COP)Varies by model
Operating Temperature Range (Heating)-15°C - 24°C
Indoor Unit Dimensions (HxWxD)Varies by model
Outdoor Unit Dimensions (HxWxD)Varies by model
Indoor Unit WeightVaries by model
Outdoor Unit WeightVaries by model

Related product manuals