-13-
Influence Effects on the Measuring Range
The measuring range depends on the light conditions and the
reflection properties of the target surface.
Influence Effects on the Measuring Result
Due to physical effects, faulty measurements cannot be excluded
when measuring on different surfaces. Included here are:
Transparent surfaces (e.g., glass, water),
Reflecting surfaces (e.g., polished metal, glass),
Porous surfaces (e.g. insulation materials),
Structured surfaces (e.g., roughcast, natural stone).
Also, air layers with varying temperatures or indirectly received
reflections can affect the measured value.
Accuracy Check of the Distance Measurement
The accuracy of the distance measurement can be checked as
follows:
Select a permanent measuring section with a length of
approx. 3 ft to 33 ft (1 m to 10 m); its length must be precisely
known (e.g. the width of a room or a door opening). The
measuring distance must be indoors; the target surface for the
measurement must be smooth and reflect well.
Measure the distance 10 times after another.
The deviation of the individual measurements from the mean
value must not exceed ±1/8” (±3.0mm). Log the measurements,
so that you can compare their accuracy at a later point of time.
Troubleshooting
Cause Corrective Measure
Temperature warning indicator (b) flashing; measurement
not possible
Measuring tool not within the Wait until the measuring
operating temperature range tool has reached the
between +14°F and 104°F operating temperature
( –10°C and +40°C)

Other manuals for Bosch GLM 20

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch GLM 20 and is the answer not in the manual?

Bosch GLM 20 Specifications

General IconGeneral
Laser ClassClass 2
Laser Type635 nm, <1 mW
DisplayLCD
Dimensions100 x 36 x 23 mm
Storage Temperature-20°C to +70°C
Protection ClassIP54
MemoryNo
Power Source2 x AAA batteries
Battery LifeApprox. 5000 measurements
Automatic DeactivationAfter 5 minutes
Units of Measurementm
Accuracy±3 mm

Related product manuals