EasyManuals Logo
Home>Bosch>Heat Pump>LM Split CS Series

Bosch LM Split CS Series Operating Instructions

Bosch LM Split CS Series
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
CS/AH Pairing | 3LM CS Series Heat
8 733 920 847 (2014/01)Revised 01-14
LM CS MODEL NOMENCLATURE
CS/AH PAIRING
KEY TO SYMBOLS
Warnings
The following keywords are defined and can be
used in this document:
NOTE indicates a situation that could result in
damage to property or equipment.
CAUTION indicates a situation that could
result in minor to medium injury.
WARNING indicates a situation that could
result in sever injury or death.
DANGER indicates a situation that will result in
severe injury or death.
Important Information
SAFETY WARNINGS
LM 024 - 1 CS C - F
SERIES WATER CONNECTIONS
LM F - Front
SIZE
COAX OPTIONS
024 C - Copper
036 N - Cupro-Nickel
048
060
CABINET CONFIGURATION
070 CS - Condensing Section
VOLTAGE DESIGNATIONS
1 - 208/1/60 & 230/1/60
Revision Level A
UNIT MODEL
Paired Air Handler
Unit 1 Unit 2
LM024-1CSC
LM024-1AVX
LM024-1AHX
LM036-1CSC
LM036-1AVX
LM036-1AHX
LM048-1CSC
LM048-1AVX
LM048-1AHX
LM060-1CSC
LM060-1AVX
LM060-1AHX
LM070-1CSC
LM070-1AVX
LM070-1AHX
Warnings in this document are identified by
a warning triangle printed against a grey
background. Keywords at the start of the
warning indicate the type and seriousness
of the ensuing risk if measures to prevent
the risk are not taken.
This symbol indicates important information
where there is no risk to property or people.
Before performing service or maintenance
operations on the system, turn off main
power to the unit. Electrical shock could
cause personal injury or death.
Installation and servicing of this equipment
can be hazardous due to system pressure
and electrical components. Only trained
and qualified personnel should install,
repair, or service the equipment.
All refrigerant discharged from this unit
must be recovered WITHOUT EXCEPTION.
Technicians must follow industry accepted
guidelines and all local, state, and federal
statutes for the recovery and disposal of
refrigerants. If a compressor is removed
from this unit, refrigerant circuit oil will
remain in the compressor. To avoid leakage
of compressor oil, refrigerant lines of the
compressor must be sealed after it is
removed.
R410A is flammable when exposed to open
flame. Recover all refrigerant prior to
brazing.

Other manuals for Bosch LM Split CS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch LM Split CS Series and is the answer not in the manual?

Bosch LM Split CS Series Specifications

General IconGeneral
BrandBosch
ModelLM Split CS Series
CategoryHeat Pump
LanguageEnglish

Related product manuals