18 | English 1 609 929 J82 • 6.6.07
Technical Data
Digital Laser Rangefinder PLR 30
Article number 3 603 K16 000
Measuring range
A)
0.2 ... 30 m
Measuring accuracy (typically) ± 2.0 mm
B)
Measuring duration (typically) <0.5 s
Lowest indication unit 1 mm
Operating temperature – 10 °C ... +50 °C
C)
Storage temperature – 20 °C ... +70 °C
Relative air humidity, max. 90 %
Laser class 2
Laser type 650 nm, <1 mW
Laser beam diameter (at 25 °C), approx.
– at 10 m distance
– at 30 m distance
6 mm
20 mm
Batteries
Rechargeable batteries
4 x 1.5 V LR03 (AAA)
4 x 1.2 V KR03 (AAA)
Battery live, approximately
– Individual measurements
– Continuous measurement
30000
5h
Automatic switch-off after approx.
–Laser
– Measuring tool (without measurement)
20 s
5 min
Weight according to EPTA-Procedure 01/2003 0.18 kg
Dimensions 66 x 110 x 34 mm
Degree of protection
(excluding battery compartment)
IP 44 (splash water
protected)
A) The working range increases depending on how well the laser light is reflected
from the surface of the target (scattered, not reflective) and with increased bright-
ness of the laser point to the ambient light intensity (interior spaces, twilight).
In unfavourable conditions (e.g. when measuring outdoors at intense sunlight), it
may be necessary to use the target plate.
B) +0.05 % at unfavourable conditions, e.g. at intense sunlight
C) In the continuous measurement function, the maximum operating temperature is
+40 °C.
Please observe the article number on the type plate of your measuring tool. The trade
names of the individual measuring tools may vary.
The measuring tool can be clearly identified with the serial number 18 on the type
plate.
OBJ_BUCH-145-003.book Page 18 Wednesday, June 6, 2007 9:02 AM