5.2 Error Codes
If an error code appears on the digital display, refer to the following chart for the
reason, and a possible remedy for the situation. If the situation requires more
support please contact Bosch at 866-642-3198.
Error Code Cause Self-diagnosis/Action
A2 Abnormal operation: FAN
1. Clean the intake air fi lter.
2. Check the fan connector.
3. Contact original installer or licensed professional.
A3 Abnormal operation: Pump 1. Contact original installer or licensed professional.
A4 Overheating of heat exchanger
1. Turn off the system for at least 30 minutes, and then restart it.
2. Contact original installer or licensed professional.
A5 Low water pressure
1. Water supplementation of manual
2. Contact original installer or licensed professional.
A6 Ignition error
1. Ensure that the main gas supply valve is open.
2. Contact original installer or licensed professional.
A7 Abnormal operation: gas valve relay "open"
1. Turn off the main gas valve.
2. Contact original installer or licensed professional.
A8 Abnormal operation: flame detection
1. Turn off the main gas valve.
2. Contact original installer or licensed professional.
AA Overheating 1. Contact original installer or licensed professional.
AB Abnormal operation: heat exchanger temperature sensor 1. Contact original installer or licensed professional.
AC Abnormal operation: DHW temperature sensor 1. Contact original installer or licensed professional.
AD Clog of condensate trap 1. Contact original installer or licensed professional.
AE Blockage of flue Pipe
1. Clean the vent terminal.
2. Contact original installer or licensed professional.
E0 Abnormal operation: Outdoor temperature sensor
1. Check the outdoor temperature sensor wiring connection.
2. Contact original installer or licensed professional.
E1 Abnormal operation: Exhaust temperature sensor
1. Check the exhaust temperature sensor wiring connection.
2. Contact original installer or licensed professional.
E2 Abnormal operation: Exhaust temperature overheating 1. Contact original installer or licensed professional.
E3 Abnormal operation: Return water temperature sensor 1. Contact original installer or licensed professional.
E4 Abnormal operation: Pressure sensor 1. Contact original installer or licensed professional.
E7 Abnormal operation: gas valve relay "Close" 1. Contact original installer or licensed professional.
EB Overheating of DHW temperature sensor 1. Contact original installer or licensed professional.
EE Abnormal operation:Data Communication 1. Contact original installer or licensed professional.
EF Abnormal operation: eep-rom error 1. Contact original installer or licensed professional.
Table 9

Other manuals for Bosch Singular 5200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Singular 5200 and is the answer not in the manual?

Bosch Singular 5200 Specifications

General IconGeneral
BrandBosch
ModelSingular 5200
CategoryBoiler
LanguageEnglish

Related product manuals