EasyManuals Logo
Home>Bosch>Heat Pump>Split CS SM048

Bosch Split CS SM048 User Manual

Bosch Split CS SM048
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
SM Split CS Series Heat Pump
SM Split CS Series Heat Pump8733825873 (2020/05)
24 | Field-Installed Accessories
Subject to change without prior notice
SmartStart Assist Specifications
Table 12 SmartStart Assist Specifications
SmartStart Assist Modes of Operations
Fig. 12 SmartStart Assist Modes of Operations (Normal and Undervoltage Condition)
SmartStart Assist Specifications
Rated Operational Voltage: 208/230VACrms +/- 15% 50-60 Hz
Environmental Operating Range: -4° to 149°F (-20° to 65°C); < 95% @ 40 C relative humidity,
non-condensing
Degree of Protection: IP20
Overvoltage: Category II
Operational Rated Current: 32 Amps
Max Starting Current:
Min Full Load Current:
80A ACrms
80A ACrms
Min time between starts: 6 minutes
Min time between stop to start: 3 minutes