6 720 818 420 (2016/09)Tronic 1000T / 2000T
Installation | 11
• Never install the appliance in rooms where the ambient
temperature can fall below 0 °C.
• If the appliance is to be fitted in a room or location where
the ambient temperature is higher than 35°C, provide
sufficient ventilation.
• Install the appliance near the most frequently used draw-
off point to keep energy losses and waiting times to a
minimum.
• Install the appliance in a room that permits the replacement
of the magnesium anode, and necessary maintenance
procedures.
Protection area 1
▶ Do not install in protection area 1.
▶ Install the appliance outside the protection area.
Fig. 6 Protection areas
5.3 Wall mounting
Vertical installation
Fig. 7 Vertical installation
Horizontal installation
Fig. 8 Horizontal installation
CAUTION:
▶ Make sure that the appliance is
connected to the DB board (electrical
board) with a connection to the earth
cable.
CAUTION: Appliance fall!
▶ Use sleeves and hooks (according with
the type of wall) that can hold the
appliance with the tank full.
Appliance A
Standard diameter models 240
Slim diameter models 340
Table 11
In case of horizontal installation ensure that
water outlet/inlet are vertical and facing
downwards.
Appliance A
ES050... 165
ES080... 350
ES100... 495
Table 12