Care and cleaning
The probe tip (5) is the most delicate part of the thermometer.
It has to be clean and intact to ensure accurate readings.
If the thermometer is accidentally used without a disposable
Hygiene cap, clean the probe tip as follows:
Very gently wipe the surface with a cotton
swab or soft cloth moistened with alcohol. Do
not use cleaners other than alcohol on the
probe tip. Use of other cleaners could damage
the tip.
Once the alcohol has dried completely, a new disposable
Hygiene cap can be put on and a temperature measurement
taken. If the probe tip is damaged, please contact your
authorized local service center.
Use a soft, dry cloth to clean the thermometer display and
product exterior. Do not use abrasive cleaners. Never
submerge this thermometer in water or any other liquid.
Store the thermometer and disposable Hygiene caps in a dry
location free from dust and contamination and away from
direct sunlight.
Additional disposable Hygiene caps (LF40) are available at
most stores selling Braun ThermoScan.
Trouble-shooting
Situation Solution
No disposable
Hygiene cap is
attached.
Attach new, clean, disposable
Hygiene cap.
Measurement before
device stabilization.
Wait until all the icons stop
ashing.
Ambient
temperature is not
within the allowed
operating range
(10–40 °C or
50–104 °F).
Allow the thermometer to remain
for 30 minutes in a room where
the temperature is between
10 and 40 °C or 50 and 104 °F.
Temperature taken is
not within typical
human temperature
range (34–42.2 °C or
93.2–108 °F).
Make sure the probe tip and lens
are clean and a new, clean,
disposable Hygiene cap is
attached. Make sure the
thermometer is properly inserted.
Then, take a new temperature.
System error. Reset the thermometer
by removing the battery and then
replacing it again, wait 1 minute,
then turn on again.
Please contact your authorized
Service Center (See Guarantee
Card).
Battery is low. Insert new battery.
Battery is too low.
Device cannot be
powered on to the
ready state.
Insert new battery.
Do you have any further
questions?
Please contact your authorized
Service Center (See Guarantee
Card).
Changing the temperature scale
Make sure the thermometer is turned o. Press
and hold down the <<start>> button. Keep
holding down the <<start>> button and after
about 3 seconds the display will start to cycle
between temperature scales (°C or °F).
Release the start button when the desired scale
is shown. This will reset the thermometer to the
new temperature scale.
English

Table of Contents

Other manuals for Braun thermoscan IRT 3030

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Braun thermoscan IRT 3030 and is the answer not in the manual?

Braun thermoscan IRT 3030 Specifications

General IconGeneral
Measurement MethodInfrared
Measurement Time1 second
Memory FunctionLast reading
DisplayLCD
Battery Type2 AAA batteries
Automatic Shut-offYes
TypeEar thermometer
Measurement SiteEar
Age RangeSuitable for all ages
HygieneDisposable lens filters
Accuracy±0.2°C (±0.4°F)