8
Changing the temperature scale
Your Braun ThermoScan is shipped with the Fahrenheit (°F) temperature scale activated. If you wish
to switch to Celsius (°C) and/or back from Celsius to Fahrenheit, proceed as follows:
Make sure the thermometer is turned o.
Press and hold down the Power button
. After about 3 seconds
the display will show this sequence: °F / SET / °C / SET.
Release the Power
button when the desired temperature scale is shown.
There will be a short beep to conrm the new setting, then the thermometer is
turned o automatically.
1
2
Care and cleaning
The probe tip is the most delicate part of the thermometer.
It must be clean and intact to ensure accurate readings.
If the thermometer is ever accidentally used without a lens lter, clean the
probe tip as follows:
Very gently wipe the surface with a cotton swab or soft cloth moistened
with alcohol. After the alcohol has completely dried out, you can put a new
lens lter on and take a temperature measurement.
If the probe tip is damaged, please contact Consumer Relations.
Use a soft, dry cloth to clean the thermometer display and exterior. DO NOT use abrasive cleaners.
NEVER submerge this thermometer in water or any other liquid. Store thermometer and lens lters
in a dry location free from dust and contamination and away from direct sunlight.
Additional lens lters (LF 40) are available at most stores carrying Braun ThermoScan.
Replacing the batteries
The thermometer is supplied with two 1.5 V type AA (LR 06) batteries. For
best performance, we recommend Duracell
®
alkaline batteries.
Insert new batteries when the battery symbol appears on the display.
Open the battery compartment. Remove the batteries and replace with
new batteries, making sure the poles are in the right direction.
Snap battery door into place.
ThermoScan
1
2
3
Only discard empty batteries. To protect the environment, dispose of
empty batteries at your retail store or at appropriate collection sites
according to national or local regulations.
Calibration
The thermometer is initially calibrated at the time of manufacture. If this thermometer is used
according to the use instructions, periodic re-adjustment is not required. If at any time you question
the accuracy, please contact Consumer Relations.