22 BRIGGSandSTRATTON.com.au
Troubleshooting
Problem Cause Correction
Engine is running, but no
AC output is available.
1. Red overload alarm light is on.
Generator is overloaded.
2. Green output indicator light not on.
Fault in generator.
3. Poor connection or defective cord set.
4. Connected device is bad.
1. See Generator Capacity. Press
RESET button on control panel.
2. Contact authorized service facility.
3. Check and repair.
4. Connect another device that is in
good condition.
Engine runs good at
no-load but “bogs down”
when loads are connected.
1. Short circuit in a connected load.
2. Engine speed is too slow.
3. Generator is overloaded.
4. Shorted generator circuit.
1. Disconnect shorted electrical load.
2. Contact authorized service facility.
3. See Generator Capacity.
4. Contact authorized service facility.
Engine will not start; shuts
down when running or
starts and runs rough.
1. Engine switch set to OFF (0).
2. Low oil indicator light comes on. Low
oil level.
3. Dirty air cleaner.
4. Out of fuel.
5. Stale fuel.
6. Spark plug wire not connected to
spark plug.
7. Bad spark plug.
8. Water in fuel.
9. Flooded.
10. Excessively rich fuel mixture.
11. Intake valve stuck open or closed.
12. Engine has lost compression.
1. Set engine switch to ON (I).
2. Fill crankcase to proper level or
place generator on level surface.
3. Clean or replace air cleaner.
4. Fill fuel tank.
5. Drain fuel tank and carburetor; fill
with fresh fuel.
6. Connect wire to spark plug.
7. Replace spark plug.
8. Drain fuel tank and carburetor; fill
with fresh fuel.
9. Wait 5 minutes and re-crank
engine.
10. Contact authorized service facility.
11. Contact authorized service facility.
12. Contact authorized service facility.
Engine lacks power.
1. Load is too high.
2. Dirty air filter.
1. See Generator Capacity.
2. Replace air filter.
Engine “hunts” or falters. Carburetor is running too rich or too lean. Contact authorized service facility.
Control panel LCD
flashing.
Maintenance reminder.
Perform scheduled maintenance, push
and hold “View” button for a minimum
of 3 seconds.

Other manuals for Briggs & Stratton P2200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Briggs & Stratton P2200 and is the answer not in the manual?

Briggs & Stratton P2200 Specifications

General IconGeneral
Running Watts1700W
Starting Watts2200W
Engine Displacement79 cc
Fuel TypeGasoline
Fuel Tank Capacity1 gallon
Run Time at 25% Load8 hours
Noise Level59 dB
Weight54 lbs
Outlets2
Voltage120V
Starting SystemRecoil
Warranty2 years