CHAPTER 2 PCL - 108
8.5. Status Response Syntax
All of the status responses begin with "PCL", Carriage Return control code and a Line Feed control code. The
response is ended by a Carriage Return and a Line Feed control code. At the end of the transaction, status
responses are ended by a Form Feed Control code. The fundamental syntax for the status response is as shown
below.
PCL<CR> <LF>
INFO TITLE<CR><LF>
KEYWORDn=DATAn<CR><LF>
KEYWORDn=DATAn<CR><LF>
.
.
.
<FF>
TITLE, KEYWORDn, and DATAn are strings which differ according to the status readback command being
operated. One or more keyword lines related to the status readback response accompany every status readback
response. The Echo command response differs from this and is as shown below.
PCL<CR><LF>
ECHO ValueField<CR><LF>
<FF>
ValueField is the decimal number which comes from the Echo command value field.
For future printers, keywords might be added. Applications in which the status readback is used should be made
to disregard lines with keywords they do not understand.
8.5.1. Set status readback location type
ESC*s#T (27)(42)(115)#(84) <1Bh><2Ah><73h>#<54h>
This command determines the status location type according to the value of #.
The location type is used in association with the location unit in order to specify an entity location for a status
request.
# = 0 specifies an invalid location. When the printer receives an Inquire Entity Command, an error response
is generated. This is the default value. When you execute a printer reset, this value is reset to 0.
# = 1 specifies the currently selected location.
# = 2 specifies all locations.
# = 3 specifies the printer's internal location.
# = 4 specifies the downloaded entity.
# = 5 specifies the user-installed card/cartridge
The location type setting is retained by the printer. When the printer does not send the set status readback
location type command in order to change the setting for an entity request, then the printer uses the currently
available location type setting.
8.5.2. Set status readback location unit
ESC*s#U (27)(42)(115)#(85) <1Bh><2Ah><73h>#<55h>
The status location unit is selected by the value of #.
The printer uses the location unit in association with the location type in order to specify an entity location
for a status request.
Type Unit
0 - invalid location
1 - currently selected location
2 - all locations
3 0 all internal entities

Table of Contents

Other manuals for Brother HL-1112

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Brother HL-1112 and is the answer not in the manual?

Brother HL-1112 Specifications

General IconGeneral
ColorNo
Print technologyLaser
Maximum resolution2400 x 600 DPI
Economical printingYes
Time to first page (black, normal)10 s
Print speed (black, normal quality, A4/US Letter)20 ppm
Printing colorsBlack
Maximum duty cycle10000 pages per month
Recommended duty cycle250 - 1800 pages per month
Number of print cartridges1
Page description languagesGDI
Mobile printing technologiesNot supported
Sound power level (standby)51 dB
Total input capacity150 sheets
Total output capacity50 sheets
Custom media width76 - 215 mm
Maximum print size216 x 356 mm
Custom media length116 - 355 mm
Paper tray media typesEnvelopes, Plain paper, Recycled paper
Paper tray media weight65 - 105 g/m²
Non-ISO print media sizesExecutive (184 x 267mm), Legal (media size), Letter (media size)
ISO A-series sizes (A0...A9)A4
Standard interfacesUSB 2.0
Mac operating systems supportedMac OS X 10.5 Leopard, Mac OS X 10.6 Snow Leopard, Mac OS X 10.7 Lion, Mac OS X 10.8 Mountain Lion
Server operating systems supportedWindows Server 2003, Windows Server 2003 x64, Windows Server 2008, Windows Server 2008 R2, Windows Server 2008 x64
Windows operating systems supportedWindows 7 Home Basic, Windows 7 Home Basic x64, Windows 7 Home Premium, Windows 7 Home Premium x64, Windows 7 Professional, Windows 7 Professional x64, Windows 7 Starter, Windows 7 Starter x64, Windows 7 Ultimate, Windows 7 Ultimate x64, Windows Vista Business, Windows Vista Business x64, Windows Vista Enterprise, Windows Vista Enterprise x64, Windows Vista Home Basic, Windows Vista Home Basic x64, Windows Vista Home Premium, Windows Vista Home Premium x64, Windows Vista Ultimate, Windows Vista Ultimate x64, Windows XP Home, Windows XP Professional, Windows XP Professional x64
Power consumption (standby)40 W
Power consumption (printing)380 W
Package depth312 mm
Package width414 mm
Package height294 mm
Package weight5300 g
Sustainability certificatesENERGY STAR
Operating temperature (T-T)10 - 32.5 °C
Operating relative humidity (H-H)20 - 80 %
Weight and Dimensions IconWeight and Dimensions
Depth238 mm
Width340 mm
Height189 mm

Related product manuals