Page 5
OPERATING CONTROLS
Model CEZ
ON/OFF SWITCH
Placing the "ON/OFF" switch in the "ON" upper position supplies
power to the brew station warmer, enables the brew circuit, and
energizes the tank refill circuit. Placing the switch in the "OFF" lower
position stops tank refilling and brewing and deenergizes the brew
station warmer. Stopping a brew cycle after it has been started will
not stop the flow of water into the decanter until the funnel is empty.
NOTE – Hot water will be available at the faucet in a limited amount
when the switch is in the "OFF" position because the tank will not
refill.
ON/OFF BREW FRONT-SIDE-REAR
ON/OFF SWITCH
Pressing the "ON/OFF" switch (indicator glowing) supplies
power to the brew station warmer, enables the brew circuit, and
energizes the tank refill circuit. Pressing the switch again (indicator
not glowing) stops tank refilling and brewing and deenergizes the
brew station warmer. Stopping a brew cycle after it has been started
will not stop the flow of water into the decanter until the funnel is
empty.
NOTE – Hot water will be available at the faucet in a limited amount
when the "ON/OFF" indicator is not glowing because the tank will not
refill.
BREW SWITCH
Momentarily pressing and releasing the switch starts a brew
cycle when the "ON/OFF" indicator is glowing.
NOTE – The "ON/OFF" indicator must be glowing to initiate and
complete a brew cycle.
BREW SWITCH
Momentarily pressing and releasing the switch starts a brew cycle when the "ON/OFF" switch is in the "ON" upper
position.
NOTE – The "ON/OFF" switch must be in the "ON" upper position to initiate and complete a brew cycle.
ADDITIONAL WARMER SWITCHES
Placing any additional warmer switch in the "ON" upper position supplies power to the associated warmer.
READY INDICATOR
This indicator glows when the preselected brew water temperature has been achieved.
Model CDBC
P1626
P1625
29079 042803