EasyManuals Logo
Home>Bunn>Coffee Maker>Single TF DBC

Bunn Single TF DBC Installation & Operating Guide

Bunn Single TF DBC
18 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
Page 4
35879.1 110507
ELECTRICAL HOOK-UP
WARNING – If the power cord is ever damaged, it must be replaced by the manufacturer or authorized service
personel with a special cord available from the manufacturer or its authorized service personel in order to
avoid a hazard. Improper electrical installation will damage electronic components. Damage caused by
incorrect electrical connections is not covered by warranty.
1. An electrician must provide electrical service.
2. Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.
NOTE - The brewer is shipped without a plug on the power cord. Qualified service personnel must select
and install the proper UL listed grounding type attachment plug specified on the rear of the brewer.
3. Install the specified plug on the attached power cord.
4. Remove the front panel beneath the sprayheads to gain access to the terminal block.
5. Connect the brewer to the power source and verify the voltage at the terminal block before proceeding.
6. If plumbing is to be hooked up later be sure the brewer is disconnected from the power source. If plumb-
ing has been hooked up, the brewer is ready for Initial Set-Up.
WARNING – Electrical connections must be made as specified above. Failure to follow these instructions can
result in personal injury, property or equipment damage.
120/208 and 120/240 volt ac
single phase, 60 Hz models
Note: This electrical service consists
of 3 current carrying conductors
(Neutral, L1 and L2) and a separate
conductor for earth ground.
L2
N
L1
G
L2 RED
WHITE
GREEN GREEN
NEUTRAL
L1 BLACK
L2 RED
WHITE
NEUTRAL
L1 BLACK
ELECTRICAL REQUIREMENTS (Models with power cord)
WARNING - The brewer must be disconnected from the power source until specified in Initial Set-Up.
Refer to Data Plate on the Brewer, and local/national electrical codes to determine circuit requirements.
N
L1
G
WHITE
GREEN GREEN
NEUTRAL
L1 BLACK
WHITE
NEUTRAL
L1 BLACK
120 volt ac single phase,
60 Hz models
Note: This electrical service consists
of 2 current carrying conductors
(Neutral and L1) and a separate
conductor for earth ground.
USER NOTICES (cont.)
37881.7002

Other manuals for Bunn Single TF DBC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bunn Single TF DBC and is the answer not in the manual?

Bunn Single TF DBC Specifications

General IconGeneral
BrandBunn
ModelSingle TF DBC
CategoryCoffee Maker
LanguageEnglish

Related product manuals