CE REQUIREMENTS
• This appliance must be installed in locations where it can be overseen by trained personnel.
• For proper operation, this appliance must be installed where the temperature is between 5°C to 35°C.
• Appliance shall not be tilted more than 10° for safe operation.
• An electrician must provide electrical service as specied in conformance with all local and national codes.
• This appliance must not be cleaned by water jet.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given instructions concerning use of
this appliance by a person responsible for its safety.
• Children should be supervised to ensure they do not play with the appliance.
If the power cord is ever damaged, it must be replaced by the manufacturer or authorized service personnel with
a special cord available from the manufacturer or its authorized service personnel in order to avoid a hazard.
PLUMBING REQUIREMENTS
This brewer must be connected to a cold water system with operating pressure between 20 and 90 psi (138 and 620
kPa) from a
1
2
" or larger supply line. A shut-off valve should be installed in the line before the brewer. Install a regulator
in the line when pressure is greater than 90 psi (620 kPa) to reduce it to 50 psi (345 kPa). The water inlet fitting is
3
8
" flare
or female quick connect.
NOTE – Bunn-O-Matic recommends
3
8
" copper tubing for all installations from the
1
2
" water supply line. A tight coil of
copper tubing in the water line will facilitate moving the brewer to clean the counter top. Bunn-O-Matic does not recom-
mend the use of a saddle valve to install the brewer. The size and shape of the hole made in the supply line by this type
of device may restrict water flow.
This equipment must be installed to comply with the National Plumbing Code of Canada and the Canadian
Food Inspection Agency. For models installed outside Canada, you must comply with the applicable
Plumbing/Sanitation Code for your area.
PLUMBING HOOK-UP
NOTE - If a backflow preventer is required by code, a shock arrestor should be installed between backflow pre-
venter and dispenser. Installing the shock arrestor as close to dispenser as possible will provide best results.
1. Flush the water line and securely attach it to the flare fitting located on bottom of brewer.
2. Turn on the water supply.

Other manuals for Bunn Single TF DBC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bunn Single TF DBC and is the answer not in the manual?

Bunn Single TF DBC Specifications

General IconGeneral
BrandBunn
ModelSingle TF DBC
CategoryCoffee Maker
LanguageEnglish

Related product manuals