Installation | 5
0870570604_RA0165-0305D_Ex_-0011_IM_en 17 / 36
5.6 Electrical Connection
DANGER
Live wires.
Risk of electrical shock.
Electrical installation work must only be executed by qualified personnel.
NOTE
The operation with variable speed, i.e. with a variable-frequency drive or a soft starter
unit, is allowed as long as the motor is admitted and the permitted motor speed range is
neither underrun nor exceeded (see Technical Data [33]).
Seek advice from your Busch representative.
Make sure that the power supply for the motor is compatible with the data on the
nameplate of the motor.
The electrical installation must comply with applicable national and international
standards.
Provide a lockable disconnect switch on the power line so that the machine is com-
pletely secured during maintenance tasks.
Provide an overload protection according to EN 60204-1 for the motor.
Busch recommends installing a D-curve circuit breaker.
Make sure that the motor of the machine will not be affected by electric or electro-
magnetic disturbance from the mains; if necessary seek advice from Busch.
Connect the protective earth conductor.
Electrically connect the motor.
NOTICE
Incorrect connection.
Risk of damage to the motor!
The wiring diagrams given below are typical. Check the inside of the terminal box for
motor connection instructions/diagrams.
5.6.1 Wiring Diagram Three-Phase Motor
NOTICE
Incorrect direction of rotation.
Risk of damage to the machine!
Operation in the wrong direction of rotation can destroy the machine in a short time!
Prior to start-up, ensure that the machine is operated in the right direction.
Determine the intended direction of rotation with the arrow (stuck on or cast).
Jog the motor briefly.
Watch the fan wheel of the motor and determine the direction of rotation just before
the fan wheel stops.
If the rotation of the motor must be changed:
Switch any two of the motor phase wires.