31
12 Volt connection
-#
)
Connect the 12 Volt electrical equipment and then the vehicle battery in accor-
dance with the 12 Volt connection diagram (Figure 8).
1
2
3
!"%
1 Connection for vehicle battery.
Feed plug from vehicle battery:
Connect + to the connecting plug's pin no. 9 (permanent positive).
Connect - to the connecting plug's pin no. 13.
2 12 Volt output to the electrical equipment.
5 outputs for the MES 250-(1-4).
6 outputs for the MES 400-(1-4).
3 Cable connection strip suitable for:
3x 0.75 mm² conductor cross section
3x 1.5 mm² conductor cross section
4x 2.5 mm² conductor cross section