EasyManuals Logo
Home>CAME>Control Systems>DIR10

CAME DIR10 User Manual

CAME DIR10
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
12 - FA01818M4A - 01/2023 - © CAME S.p.A. -
Description
001DIR10
Pair of external photocells 12 - 24 V AC - DC. Range: 10 m.
001DIR20
Pair of external photocells 12 - 24 V AC - DC. Range: 20 m.
001DIR30
Pair of external photocells 12 - 24 V AC - DC. Range: 30 m.
A B
Description of parts
1
Casing base
2
Control board
3
Casing cover with infrared screen
4
Fastening screw
5
Base for recessed installation
C
Size
Technical data
MODELS DIR10 DIR20 DIR30
Power supply (V - 50/60 Hz)
12 - 24 AC
- DC
12 - 24 AC
- DC
12 - 24 AC
- DC
Maximum absorbed current
(mA)
60 60 60
Operating temperature (°C) -20 ÷ +55 -20 ÷ +55 -20 ÷ +55
Protection rating (IP) 54 54 54
Storage temperature (°C) -25 ÷ +70 -25 ÷ +70 -25 ÷ +70
Average life (cycles) 100000 100000 100000
Contact range (mA) 500 500 500
(**) Before installing the product, keep it at room temperature where it has
previously been stored or transported at a very high or very low temperature.
(***) The average product life is a purely indicative estimate. It applies to compliant
usage, installation and maintenance conditions. It is also infl uenced by other
factors, such as climatic and environmental conditions.