EXAMPLE SET-UPS
Example set-up without VA/01
XDV/304
Lb
La
Lc
VAS/101
LHS
Cable length
Section Cable type
La, Lb VCM/1D or UTP CAT5
Lc 2x1mm² or 2x2.5mm²
Section Max. section length (m)
La + Lb 100 VCM/1D or 60 UTP/CAT 5
Lc 25 (2x1mm²) or 60 (2x2.5mm²)
Maximum number of internal receivers per cable type
VCM/1D
Master 321
Slave 037
UTP CAT5
Master 1
Slave 7