8555-M210-O1 Rev R 758C Owner’s 36
EVENT COUNTER
The 758C weight indicator has been designed with an Event Counter type of security seal.
When selected, the 758C will display two 3-digit numbers representing the Calibration and
Configuration counters.
Calibration Counter
The calibration counter is incremented when a value in the calibration part of setup is
changed (SetGC, CALGC, OPGC, int, Unit, UnS, dPP, CAP, FLt, F, br, Sr, CAL,). The
counter is only incremented 1 time even if more than one parameter is changed each time
through setup.
Configuration Counter
The configuration counter is incremented when a value in the configuration part of setup is
changed (Hold, bAnd, trA, PUO, niCAd, SLEEP, ASH). The counter is only incremented
1 time even if more than one parameter is changed each time through setup.
To Review the Event Counter:
1. If indicator is on, press the ON/OFF key.
2. Press and hold the UNITS key and then press the ON/OFF key.
3. The indicator will perform a display test (turn on all digits), show the software version for
a few seconds and then change to show CAL1 and CHC.
4. Release the UNITS key.
5. The display will then show two 3-digit numbers.
The left number represents the setup Calibration counter.
The right number represents the Configuration counter.
6. To return to the normal operation, press the UNITS key.
7. Otherwise press the ON/OFF key to turn off the indicator.
CARE AND CLEANING
DO NOT submerge indicator in water, pour or spray water directly on indicator.
DO NOT use acetone, thinner or other volatile solvents for cleaning.
DO NOT expose equipment to temperature extremes.
DO NOT place equipment in front of heating/cooling vents.
DO clean the indicator with a damp soft cloth and mild non-abrasive detergent.
DO remove power before cleaning with a damp cloth.
DO provide clean AC power and adequate protection against lightning damage.
DO keep the surroundings clear to provide clean and adequate air circulation.