OUTDOOR UNIT DIAGNOSTIC GUIDES
Table 16—Diagnostic Guides
OPERATION LAMP TIMER LAMP DISPLAY LED STATUS
1 time
X E0 Indoor unit EEPROM parameter error
2 times
X E1 Indoor / outdoor units communication error
3 times
X E2 Zero-crossing signal detection error
4 times
X E3 Indoor fan speed has been out of control
5 times
X E4 Indoor room temperature sensor T1 open circuit or short circuit
6 times
X E5 Evaporator coil temperature sensor T2 open circuit or short circuit
7 times
X EC Refrigerant leakage detection
1 time
O F0 Overload current protection
2 times
O F1 Outdoor ambient temperature sensor T4 open circuit or short circuit
3 times
O F2 Condenser coil temperature sensor T3 open circuit or short circuit
4 times
O F3 Compressor discharge temperature sensor T5 open circuit or short circuit
5 times
O F4 Outdoor unit EEPROM parameter error
6 times
O F5 Outdoor fan speed has been out of control
1 time
P0 IPM malfunction or IGBT over-strong current protection
2 times
P1 Over voltage or over low voltage protection
3 times
P2 High temperature protection of IPM module or compressor top
4 times
P3* Outdoor ambient temperature too low.
5 times
P4 Inverter compressor drive error
6 times
P5 Indoor units mode conflict (multi-zone ONLY)
Olight Xoff ☆(flash

Table of Contents

Other manuals for Carrier 38MHRBC12AA1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Carrier 38MHRBC12AA1 and is the answer not in the manual?

Carrier 38MHRBC12AA1 Specifications

General IconGeneral
BrandCarrier
Model38MHRBC12AA1
CategoryAir Conditioner
LanguageEnglish

Related product manuals