EasyManuals Logo

Carrier 38MHRBQ18AA3 User Manual

Carrier 38MHRBQ18AA3
74 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #30 background imageLoading...
Page #30 background image
30
DIAGNOSIS AND SOLUTION (CONT)
Zero crossing detection error diagnosis and solution (E2)
Error Code E2
Malfunction decision conditions
When the PCB does not receive a zero crossing signal feedback for 4 minutes or the zero crossing
signal time interval is abnormal.
Supposed causes
S Connection mistake
S PCB faulty
Troubleshooting
Check if the connections and
power supply are normal.
Correct the connections. Turn on the
unit when the power supply is good.
No
Yes
Indoor main PCB is
defective. Replace indoor
main PCB.

Table of Contents

Other manuals for Carrier 38MHRBQ18AA3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Carrier 38MHRBQ18AA3 and is the answer not in the manual?

Carrier 38MHRBQ18AA3 Specifications

General IconGeneral
BrandCarrier
Model38MHRBQ18AA3
CategoryAir Conditioner
LanguageEnglish

Related product manuals