Page #6 background imageLoading...
Page #6 background image
OPERATING TEMPERATURE
MANUAL OPERATION
Manul operation can be used temporarily in case you can not find the remote controller or
its batteries are exhausted.
Open and lift the front panel up to an angle until
it remains fixed with a clicking sound.
Push the button until the AUTO indicator is lit,
the unit will work in forced AUTO mode (the
default setting temperature is 24 ).
Close the panel firmly to its original position.
Once you push the manual button, the operation
mode is shifted in an order as: AUTO, COOL, OFF.
Push the manual button until the OPERATION
indicator flashes rapidly (five times per second),
the unit now is operating in forced COOL
mode. This is used for testing purposes only, .
When the OPERATION indicator goes off, the
air conditioner is OFF.
To restore the remote controller operation, use the
remote controller directly.
CAUTION:
1
3
2
4
COOL
AUTO
AUTO
COOL
Manual
control button
AUTO/COOL
AUTO/COOL
(For 16000Btu/h Models)
(For 16000~21000Btu/h Models)
Open and lift the front panel up to an angle
until it remains fixed with a clicking sound.
Push the AUTO button and the air conditioner
will run in AUTO mode.
Close the panel firmly to its original position.
The "COOL" mode on the control board is only
provided for testing purposes.
NOTE:
1
3
2
Mode
Cooling operation
Heating operation
Drying operation
Temperature
1. If air conditioner is used outside of the above conditions, certain safety protection
features may come into operation and cause the unit to function abnormally.
2. Room relative humidity less than 80%. If the air conditioner operates in excess of this
figure, the surface of the air conditioner may attract condensation. Please sets the vertical
air flow louver to its maximum angle (vertically to the floor), and set HIGH fan mode.
3. Optimum performance will be achieved within these operating temperature.
Room temperature
Outdoor temperature
17 C 32 C
18 C 43 C
0C 30C
-7 C 24 C
17 C 32 C
11C 43C
~
CAUTION:
~
~
~
( -5 C 43 C:For the models with
low temperature cooling system)
~
~
~
Manual
control button
Manual
control button
Manual
control button

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Carrier AI10H-2 and is the answer not in the manual?

Carrier AI10H-2 Specifications

General IconGeneral
BrandCarrier
ModelAI10H-2
CategoryAir Conditioner
LanguageEnglish

Related product manuals