PECIFICATIONS
S
28
208743 Rev. 1
6.1-1 Hydraulics
6.1-2 Auxiliary Valve Functions
Truck Relief Setting
Minimum – 2300 psi (160) bar
Maximum – 2600 psi (180) bar
Hydraulic Oil
Cascade attachments are compatible with SAE 10W
petroleum base oil per Mil. Spec. MIL-0-5606 or
MIL-0-2104B.
Use of synthetic or aqueous base hydraulic oil is not
recommended. Contact Cascade if fire resistant
hydraulic oil must be used.
Tilt back
Hoist up
Hoist down
Tilt forward
FORK POSITIONER WITH
SOLENOID VALVE
A Sideshift Left
A Forks Out (press knob button)
B Sideshift Right
B Forks In (press knob button)
A
B
A
A
B
B
FORK POSITIONER WITH
STANDARD VALVE
A Sideshift Left
B Sideshift Right
C Forks Out
D Forks In
A
B
C
C
D
D
B
FORK POSITIONER WITH
SEQUENCE VALVE
A Sideshift Left – Forks Out
B Sideshift Right – Forks In
A
A
A
B
B
Truck Flow Volume
55F 100F/120F
Minimum 3 GPM (11 L/min.) 4 GPM (15 L/min.)
Recommended 4 GPM (15 L/min.) 5 GPM (19 L/min.)
Maximum 5 GPM (19 L/min.) 6 GPM (23 L/min.)