8. DIAGNOSTIC OPERATIONS
8-1. To start the diagnostic operation
1. Make MAC operation.
2. Turn the mode switch to PGM position.
3. Input "99999999" and press "SUB TOTAL" key.
Note : Do not issue the receipt under REG / RF / X / Z mode before execute the diagnostic.
If the machine issued a receipt, the diagnostic does not start.
8-2. Check items
The following test can be checked in the test mode.
1. Key code check
2. Switch check
3. Individual function check
4. Country code write operation for EEPROM (PAD data)
0 0 - 0 0 - 0 0
0 0 - 0 0 # 0 0 0 2
- d1d2d3d4 - - d5d6d7
Print ing Layout
0 0 - 0 0 - 0 0
0 0 - 0 0 # 0 0 0 2
- 2 8 6 2 - - 1 - -
Receipt sample
d1d2d3d4 : Version No.
d5 : PAD condition
0 : Japan
1 : Export (ADD2)
2 : US / Canada
3 : Export (ADD3)
4 : Export (ADD1)
d6 :
0 : Non taxable (Japan)
1 : Taxable (Japan)
- : Export version
d7:
0 : 118ER (Japan)
1 : 108ER (Japan)
- : Export version