CHM 025 030 040 050 063 075 090 110 130 150 CHPC 63 71 80 90
B3 0.02 0.04 0.08 0.15 0.30 0.55 1 3 4.5 7 0.05 0.07 0.15 0.16
B8 0.02 0.04 0.08 0.15 0.30 0.55 1 1.4 1.7 5.1 0.05 0.07 0.15 0.16
B6/B7 0.02 0.04 0.08 0.15 0.30 0.55 1 2.2 3.3 5.4 0.05 0.07 0.15 0.16
V5 0.02 0.04 0.08 0.15 0.30 0.55 1 3 4.5 7 0.05 0.07 0.15 0.16
V6 0.02 0.04 0.08 0.15 0.30 0.55 1 2.2 3.3 5.1 0.05 0.07 0.15 0.16
CHM 025/090 CHM 110/150 CHPC
Lubricant Synthetic Mineral Mineral Mineral Synthetic
°C ambient -25°C/+50°C -25°C/+50°C -5°C/+40°C -15°C/+25°C -25°C/+50°C
ISO VG320 VG320 VG460 VG220 VG320
AGIP TELIUM BLASIA 320 BLASIA 460 BLASIA 220 TELIUM
VSF 320 VSF 320
SHELL TIVELA OMALA OMALA OMALA TIVELA
OIL S 320 OIL 320 OIL 460 OIL 220 OIL SC 320
IP TELIUM VSF MELLANA MELLANA MELLANA TELIUM VSF
OIL 320 OIL 460 OIL 220
Lubrication
B3
TERMINAL BOX POSITION
N.B. The position of the terminal box always refers to
the B3 position.
4
3
2
1
1
Terminal Box Position
26
C - SERIE BETRIEBE- UND wARTUNGSANLEITUNG
CHM - SERIE BETRIEBE- UND wARTUNGSANLEITUNG
CHM 025/090 CHM 110/150 CHPC
Lubricant Synthetic Mineral Mineral Mineral Synthetic
°C ambient -25°C/+50°C -25°C/+50°C -5°C/+40°C -15°C/+25°C -25°C/+50°C
ISO VG320 VG320 VG460 VG220 VG320
AGIP TELIUM BLASIA 320 BLASIA 460 BLASIA 220 TELIUM
VSF 320 VSF 320
SHELL TIVELA OMALA OMALA OMALA TIVELA
OIL S 320 OIL 320 OIL 460 OIL 220 OIL SC 320
IP TELIUM VSF MELLANA MELLANA MELLANA TELIUM VSF
OIL 320 OIL 460 OIL 220
LUBRICATION
h) Check the oil level ;
On the mounting position tables the oillevel plug is shown. Please refer to those tables and be sure
that the oillevelis correct according the mounting position. Usea wire as shown below for checking
the oil level entering from the level plug. The oil level must be within 3mm from the plugs entering
point as shown below. If you need to adjust the oil level refer to the oil tables givenon this manuel
and be sure you are using the correct oil. Observe the nameplate for the correct oil.
Do not mix synthetic oils with mineral which can cause serious damage on the gear unit.
I riduttori dalla grandezza 025 alla grandezza 090 vengono forniti completi di olio sintetico pertanto non richiedono alcuna manutenzione.
I riduttori grandezza 110, 130 e 150 vengono forniti completi di olio minerale nella quantità prevista in posizione di montaggio B3, sarà
cura del cliente adattare la quantità di olio alla posizione di montaggio ed inoltre sostituire il tappo di carico, fornito chiuso per motivi
di trasporto, con quello dotato di sfiato allegato al riduttore. La mancata installazione del tappo di sfiato può creare pressioni interne
con conseguente perdita di olio dagli anelli di tenuta. Per le grandezze 110, 130 e 150 dopo circa 300 ore lavorative, periodo di rodaggio,
si consiglia la sostituzione dell’olio.