EasyManuals Logo
Home>Cisco>Network Router>ASR 1002-X

Cisco ASR 1002-X User Manual

Cisco ASR 1002-X
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
13
Warning
Installation of the equipment must comply with local and national electrical codes.
Statement 1074
Warning
When installing or replacing the unit, the ground connection must always be made first and disconnected last.
Statement 1046
Warning
This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the absence of
a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if
you are uncertain that suitable grounding is available.
Statement 1024
Warning
This unit has two power supply connections. All connections must be removed to de-energize the unit.
Statement
1028
Warning
This product relies on the building’s installation for short-circuit (overcurrent) protection. Ensure that the
protective device is rated not greater than: AC power supplies for the Cisco Aggregation Services Routers: 120
VAC, 20A U.S. maximum. DC power supplies for the Cisco ASR 1006 Router: 50A U.S. maximum; Cisco ASR 1004
Router: 40A U.S. maximum: Cisco ASR 1002-X Router: 30A (–48V) U.S. and 40A (+24V) U.S. maximum.
Statement 1005
Figure 10 shows the AC power supply for the Cisco ASR 1002-X Router.
Figure 10 AC Power Supply for the Cisco ASR 1002-X Router
Table 1 describes the AC power supply LEDs on the Cisco ASR 1002-X Router.
Table 1 Cisco ASR 1002-X Router AC Power Supply LEDs
1
Chassis ESD socket
5
AC power supply fan
2
AC power supply slot number 0
6
AC power supply captive installation screw
3
AC power supply On (I) /Off (O) switch
7
AC power supply slot number 1
4
AC power supply LEDs
8
AC power inlet
OUTPUT INPUT
FAIL
OK OK
FAN
OUTPUT INPUT
FAIL
OK OK
FAN
This unit might have more than
one power supply connection.
All connections must be removed
to de-energize the unit.
This unit might have more than
one power supply connection.
All connections must be removed
to de-energize the unit.
0
1
8 7
280288
41 5 63
2

Other manuals for Cisco ASR 1002-X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ASR 1002-X and is the answer not in the manual?

Cisco ASR 1002-X Specifications

General IconGeneral
BrandCisco
ModelASR 1002-X
CategoryNetwork Router
LanguageEnglish

Related product manuals